Tobii TX300 Eye Tracker
The Tobii TX300 Eye Tracker sets a new standard for remote eye trackers. Its unique combination of 300 Hz sampling rate, very high precision and accuracy, robust eye tracking and compensation for large head movements extends the possibilities for unobtrusive research of oculomotor functions and human behavior. Tobii TX300 offers flexibility with numerous stimuli set-up and software options.
(read more...)
|
|
Tobii x50 Eye Tracker
Tobii provides a true revolution in eye tracking. Eye tracking is now effective to use and available to anyone, without requirement for extensive eye tracking experience, while not compromising tracking quality. It is not integrated into a monitor, but can be attached to any monitor or used to perform eye tracking relative to a physical scene, a TV or projection screen. However, it is slightly more obtrusive, since it is clearly visible, and it is not as easy to use given the need for hardware calibration each time it is moved.
Analysis set ups with Tobii x50:
- Eye tracking on any display
- Eye tracking on TV or projection screen
- Eye tracking on physical objects
(read more...)
|
|
Qualisys Motion Capture System
Qualisys supplies a range of hardware and software products for motion capture and analysis of movement data. The key components of the system are the Oqus cameras and the Qualisys Track Manager (QTM) software. For advanced analysis of the movement data Qualisys supplies third party software products such as Visual3D from C-Motion, Inc. Measurement data can be exported in different standard formats for use in customer-developed and other third party software. The Qualisys products are designed to meet the highest demands for quality, simplicity, speed and precision. Systems, built from the Qualisys products, are flexible, mobile and expandable and are therefore easy to adapt to varying needs in industry, research and clinical use.
- ProReflex, Qualisys motion capture camera
The compact design of the ProReflex MCU permits multiple specialized digital processors to be mounted within the camera housing. This design allows the camera to process video data directly and convert it into coordinates. The resulting digital data is easily downloaded through simple daisy chain wiring without introducing signal noise or degradation. A ProReflex MCU system is made up of between one and thirty-two cameras depending on the user’s measurement needs. The system is flexible and cameras can be added as the needs change.
- Qualisys Track Manager
QTM is a software that allows the user to perform real time 2D and 3D motion capture using Qualisys motion capture hardware. QTM is designed to meet the needs of the advanced as well as the inexperienced users in many application areas ranging from industry to medical research.
(read more...)
|
|
Magnetic Stimulators
Induce a small transient electrical current in human tissue by a very strong magnetic field created by a stimulating coil held close to the area of the body to be stimulated. It is non-invasive, painless and is used in diagnosis, prognosis and therapy in a range of nervous and psychiatric disorders, being able to stimulate the human cortex and all spinal roots, as well as peripheral nerves, easily and painlessly.
- Magstim 200²
Based upon the original Magstim design, the new Magstim 200² monophasic transcranial stimulator draws upon the years of knowledge and expertise gathered in both the clinical and research environments. The result is an innovative design that will enhance the company's reputation and establish the new Magstim range as the system of preferred choice.
- BiStim²
BiStim² provides an effective upgrade path that allows users to take full advantage of the Magstim 200² modularity. The potential to combine two units offers fully programmable paired pulse stimulation through a single stimulating coil. The ability to change pulse intervals and to control independently the power level of each Magstim 200² allows for sub- and supra-threshold conditioning and secondary pulses to investigate inhibitory and facilitatory circuits.
- Rapid²
BiStim2 Repetitive Transcranial Magnetic Stimulation (rTMS) works by inducing electrical currents in tissue using a non-invasive stimulating coil at frequencies of up to 100Hz. The stimulating coil is placed near the intended site of stimulation and trigger pulses initiate brief magnetic pulses. The magnetic fields can pass through clothing, tissue and bone to reach otherwise inaccessible areas. One feature of magnetic stimulation is that it is less likely to stimulate pain fibres at the skin surface, reducing the discomfort when compared with conventional electrical stimulation. Magstim Rapid² magnetic stimulators combine stimulation frequencies from 1Hz to 100Hz with a touch screen interface which controls every aspect of the stimulator's control and operation. This new range of rapid rate stimulators replaces the well established Magstim Rapid and Magstim Super Rapid and has been developed as a result of extensive consultation with existing users throughout the world, both in the clinical and research arenas.
(read more...)
|
|
MAXNC 15 CL
The MAXNC 15 CL2 is a closed loop version of the MAXNC 15 stepper machine but using the MAXNC new CL2 motion system for control. This new controller run 4 axes from a single parallel port from any PC, 66 mega Herts or faster (486, Pentium, AMDK, etc.)from DOS or from WINDOWS. The control reads the encoders at a rate of over 60,000 times a second and the feed-back is analyzed by the software. Based on the position of the encoders, the outputs to the motors are advanced, retarded or modified as needed. The speed at which the software operates also allows the control of the spindle motor speed from the CNC program. The servo motors used in the CL2 systems are of step configuration to obtain very fast acceleration an deceleration rates, important in continuous contouring operations. Machine operates at up to 60 inches per minute with the standard 20 threads per inch screws. The machine comes equipped with combination HOME and LIMIT switches and a socket for the 3D digitizer.
(read more...)
|
|
MicroTouch™ M170 17" LCD Touch Monitor
The MicroTouch™ M170 Touch Monitor from 3M was designed to be different. The result of extensive customer research, innovative industrial design, and years of touch technology expertise, the M170 monitor's unique mechanical and technology features offer premium performance for a wide-range of implementations.
- Ships with all cables fully attached and ready for use
- Display angle adjustable within a 95° range
- Out-of-the-box wall mountable
- Peripheral Attachment System - Mount your preferred peripheral device or simultaneously mount multiple peripheral devices
- Cables, connections and power supply are all concealed, and peripheral cables can be concealed as well
- Complete multimedia package, lockable on-screen display controls, and full VESA-mounting compliance
(read more...) |
|
TDT Data Acquisition
TDT offers a number of versatile, user-programmable DSP-based systems for real-time stimulus generation and data acquisition featuring our System 3 line of real-time processors. Systems with 24-bit Sigma-Delta A/D and D/A converters offer unparalleled precision and signal-to-noise ratios while those with 16-bit PCM converters are best-suited for applications that require minimal group delay. You can customize the DSP function using circuits designed with TDT’s RPvds Visual Design Studio. These circuits can be controlled directly through RPvds, TDT applications software, or through custom code written using MATLAB, Visual C++, Visual Basic, or any language that supports ActiveX controls.
- RZ2 Z-Series Base Station
The RZ2 processes and filters acquired signals and can be used to control digital I/O and/or generate analog signals. Designed for up to 256-channel data acquisition, the RZ2 is the first in TDT’s Z-Series line of ultra high performance processors. Z-Series processors feature four or eight ultra fast digital signal processors networked on a novel bus architecture that speeds both onboard communication and memory access. Faster clock speeds and enhanced processing power not only improve channel count, but also allow for simultaneous acquisition on all 256 channels at sampling rates up to ~50 kHz. High bandwidth data is streamed from a Z-Series PreAmp to the RZ2 over a fast fiber optic connection. Our innovative Optibit optical PC interface ensures fast and reliable data transfer from the RZ2 to the PC. The RZ2 also features 16 channels of analog I/O, 24 bits of digital I/O, two legacy optical inputs for Medusa PreAmps, and an onboard LCD for system status display.
- Z-Series Preamplifiers 128 channel
TDT’s high-count Z-Series preamplifiers feature a fast new fiber optic connection capable of simultaneously transferring up to 256 channels at full precision. This extended bandwidth supports sampling rates up to ~50 kHz and improves signal fidelity, spike discrimination, sorting, and analysis. Used exclusively with Z-Series base stations, preamps are available in 64, 128 or 256-channel models. Our custom 18-bit hybrid A/D architecture offers the advantages of Sigma-Delta converters at significantly lower power. Dual-battery architecture allows one battery to power the preamp while its backup is charged over an isolated charging circuit. LEDs indicate battery status as well as spike detection and clipping on each channel.
- Optibit Interface
Our high-speed interfaces provide communication between your PC and System 3, zBus-based, hardware components. Designed for users requiring real-time control of System 3 devices, each consists of a PCI card for your computer and one or more interface modules that mount in zBus device caddies. These interfaces also provide automatic device identification, system initialization and a single clock that phase-locks all devices across all caddies. The Optibit version, featuring fiber optic data transmission and improved throughput, is also available. This design minimizes the potential for communication errors caused by electromagnetic interference and allows lossless data transmission over longer distances
(read more...)
|
|
CED 1902
The 1902 is a versatile modular unit designed to work with modern computer-controlled data acquisition systems. Developed for a broad range of applications, the 1902 accepts biological and instrumentation signals from a wide variety of sources.
It is available in single or multi channel configurations. Communication with the computer is achieved through a serial line, allowing multiple sets of units to be controlled simultaneously.
For EMG, EEG, ECG, ERG, Evoked response, Skin Conductance, Tremor Measurement, Auditory Brainstem and many more life science and engineering research applications. (read more...)
|
|
CED Micro 1401
The Micro1401 mk 2 is a low cost, versatile data acquisition unit. The on-board processor with high speed memory is optimised for real time processing, free from the constraints of the host computer operating system. Fast and accurate sampling coupled with simultaneous output offers extensive on-line experimental control. The Micro1401 records waveform data, digital (event) and marker information and can simultaneously generate waveform and digital outputs in real-time for multi-tasking experimental control. It features high-speed waveform capture at rates up to 500kHz with 16-bit resolution. The 32-bit RISC processor allows complex on-line analysis while freeing time for the host computer to perform other tasks, such as data manipulation and further analysis.
- Waveform I/O
4 channels of 16-bit waveform input, ±5V, or ±10V more details Up to 28 waveform inputs via expansion units 2 waveform output channels, 12-bit, ±5V or ±10V
- Digital I/O
16 digital inputs, 8 with change-of-state detection to micro-second accuracy 16 digital outputs, 8 clocked for microsecond accurate switching Handshake lines for byte input and output
- Clock and Events
5 programmable clocks with 100 nS resolution more details BNC socket for clock inputs and event (clock start) connections Synchronisation option for multiple 1401s
- Processor and Memory
32-bit ARM7 processor running at 75 MHz 1 MByte of read-write memory, option of 2 MBytes Flash memory holding operating firmware and self-test code
(read more...)
|
|
OptiTrack Optical Motion Capture
Complete system of 6 infrared cameras sampling at 100Hz, included with software toolkits (Point Cloud, Rigid Body and Arena) to track single markers up to Full Body Motion Capture.
(read more...)
|
|
UPF - Trigger TTL device for E-Prime 2 Pro and 3
The device include 8 logical TTL input/output ports (0 to +5V). Each port has a temporal resolution of 50 ns and the complete output voltage transition from GND to 5V takes approximately 400 µs. The device is controlled via microprocessor at 12 MHz.
A Windows compatible .dll enable communication with the device.
- Full E-Prime 2 Pro, 3 compatible
- Direct USB software
- Easy to use it
- Guaranted millisecond accuracy
- Compatible with other applications
- Standard BNC connection
(read more...) |
|
|
|
|
|
|
|